PLC Automatic Control Remote Monitoring Bipolar Medical Dialysis Pure Water Preparation Device for Medical Institution

Customization: Available
Certification: ISO9001, RoHS, CE, ISO13485
Salt Rejection Rate: 99.0%

Product Description

Medical Dialysis Pure Water Device
Basic Info.
Model NO.
MOL-TX-CSA/MOL-TX-CSB/MOL-TX-CSC/MOL-TX-CSD
Application
Hospital Dialysis Use
Capacity
Customized
Core Components
Pressure Vessel, Pump, PLC
Power(W)
3kw
Voltage
220V, 380V, or Customized
Warranty
1 Year
Machinery Test Report
Provided
Video Inspection
Provided
Weight (Kg)
400
Control System
PLC +HMI Auto and Manual
Material
Stainless Steel/UPVC
Production Capacity
50000sets/Year
Product Description

PROFESSIONAL HEMODIALYSIS WATER TREATMENT SYSTEM FOR MEDICAL-GRADE WATER PURIFICATION

Our Dialysis Pure Water Machine is a state-of-the-art hemodialysis water treatment system designed to deliver medical-grade pure water that fully complies with international standards. This system adopts advanced purification technology, which can efficiently remove various contaminants from raw water, fully complying with authoritative domestic and international medical standards such as China YY 0572-2015 and American AAMI/ASAIO.

The system is equipped with a PLC intelligent control system, supporting one-button start/stop, automatic water production and online monitoring, with automatic fault alarm. It features user-friendly operation and reliable performance. The system has obtained ISO certification and CE compliance certification, providing a reliable and uninterrupted pure water supply for critical patient care.

Specification
Model Flow Capacity Power Feed For Dialysis Machine (Sets)
MOL-TX-CSA 200-600L/H 3.5KW 1-15
MOL-TX-CSB 600-1300L/H 6.0KW 15-30
MOL-TX-CSC 1300-2500L/H 9.0KW 30-50
MOL-TX-CSD 2500-4000L/H 12.0KW 50-100
Functional Advantages
Bipolar RO Technology

ADVANCED BIPOLAR REVERSE OSMOSIS TECHNOLOGY

The system utilizes a sophisticated dual-stage reverse osmosis direct-supply water treatment process that ensures consistently stable and high-purity water output. Both configurations can operate independently, providing seamless emergency water supply.

PLC Automation

INTELLIGENT PLC AUTOMATION

Equipped with a state-of-the-art PLC control system integrated with an intuitive HMI touch screen interface. It simplifies operation procedures, reduces labor intensity, and minimizes human error.

Water Monitoring

REAL-TIME QUALITY MONITORING

Features continuous online monitoring and instant display of water conductivity levels, ensuring compliance with stringent medical water quality standards and safeguarding patient safety.

Dual-Material Construction

DUAL-MATERIAL CONSTRUCTION

Available in premium stainless steel or economical UPVC materials. The corrosion-resistant design ensures long-term durability and maintains water purity throughout the lifecycle.

Flexible Capacity

FLEXIBLE CAPACITY CONFIGURATION

Offers scalable water production from 200L/H to 4000L/H. Suitable for various facility sizes, from small dialysis clinics to large hospital centers.

Core Applications
Hospital Hemodialysis Departments

Serving comprehensive hospital nephrology departments, providing medical-grade pure water meeting AAMI/ASAIO standards.

Renal Dialysis & Nephrology Clinics

Delivers ultra-pure water compliant with YY0572-2015 standards specifically for kidney dialysis machines.

Dialysis Center Medical Institutions

Centralized water solutions for large-scale treatment centers with integrated intelligent monitoring.

Equipment Service & Maintenance

Supports dialysis machine testing, calibration, and maintenance requiring consistent standardized pure water.

Product Showcase
System View 1 System View 2 System View 3
Frequently Asked Questions
Does your dialysis pure water system meet international medical device standards?
Yes, it fully complies with international standards such as the USA AAMI /ASAIO standard and YY0572-2015 standard. System design strictly complies with Yy0793.1-2010 standard. The product water quality meets the strict requirements of hemodialysis, ensuring clinical safety.
What are the common pollution problems in RO membranes and how to handle them?
Common contaminants include colloids, organic matter, scaling, and biological contamination. Prevention involves proper pre-treatment and regular flushing. Treatment includes targeted chemical cleaning (alkaline for organics, acidic for scaling).
What causes a sudden drop in water production?
Common causes include pre-treatment blockage, RO membrane contamination, insufficient inlet water pressure, or abnormal regulation. Troubleshooting starts with checking inlet pressure, then pre-treatment pressure differences, and finally RO membrane cleaning or replacement.
What key data should be recorded in daily monitoring?
Core data includes influent water parameters, pre-treatment/RO system parameters, product water quality, and operation records. This helps in identifying hidden dangers and tracing problems for compliant maintenance.
What trade and payment terms are accepted?
We accept various Delivery Terms including FOB, CFR, CIF, EXW, and DDU. Accepted Payment Currencies are USD and EUR, via T/T, L/C, Credit Card, or Western Union.